Logo stampa
800 185 075 800 185 075

LANDFILL FOR NON-HAZARDOUS WASTE IN VOLTANA, LUGO

Via Traversagno 30, Voltana di Lugo (RA)

  • 1 / 2   Voltana - Lugo Landfill for Non-Hazardous Waste
  • 2 / 2   Voltana - Lugo Landfill for Non-Hazardous Waste

The landfill is located in Voltana di Lugo (RA) and forms part of the Lugo Integrated Waste Centre, which also comprises a municipal solid waste dry fraction selection plant managed by Akron S.p.A. (a subsidiary of Herambiente S.p.A.) and the composting plant managed by Herambiente.

Page updated 25 August 2015

 
    Landfill type
    Municipal solid waste and special non-hazardous waste
    Operational status
    Waste delivery resumed in August 2011 after a suspension starting in 2008 following the granting of the above-ground authorisation
    Envisaged saturation
    2015
    Permitted acceptable waste
    Max 250,000 tonnes of waste for disposal and 50,000 tonnes of recovered waste
    Overall capacity
    760,000 m of which 250,000 m above-ground
    Placement type
    4-metre thick layers

    Compacting and re-covering of the waste with earth, stabilised organic fraction, fireproof and waterproof liner.

    Groundwater is protected by a specific leachate collection and management plant, which includes a sand drainage layer (50 cm) crossed by a herringbone drainage network of perforated tubes placed laterally and connected to a central collector that conveys the leachate to four collection/lifting wells. Subsequently, four extraction pumps send the leachate extracted from the landfill site to be stored in a special tank before being transferred by tankers to the authorised treatment plant.

    The biogas produced by the landfill site is captured by a collection system consisting of a drainage well that channels the biogas to the aspiration plant via a specific supply network and finally sends it to high-temperature gas flaring for combustion.

    Compacted mineral layer at the first seal level consisting of clay material. The second watertight seal level comprises a Bentonite mat, a 2 mm HDPE sheet protecting the two previous levels and a sand drainage layer (bottom drainage of the leachate).

    The final top covering consists of a regulation layer, biogas drainage, a clay waterproofing layer, water drainage and a surface layer of topsoil.

    For the final covering of the embankments, geomembranes will be used in place of gravel drainage layers and a Bentonite geocomposite with a sealing function will be used in place of the clay layer (all geocomposites mentioned above must have characteristics that are strictly equivalent to the requirements of Legislative Decree 36/2003 in relation to the respective functional layers).

    The environmental matrices and emissions monitored as environmental surveillance of the potential impact of the operational management of the landfill are:

    • rainwater;
    • groundwater;
    • surface water (receiving vessels);
    • leachate;
    • atmospheric particulate;
    • monitoring of biogas composition;
    • landfill emissions;
    • air quality (Odorous substances);
    • monitoring of leachate explosiveness on the management network;
    • noise monitoring.