Canvas in Termovalorizzatore di Modena_ENG

  • Immagine Canvas Mobile Termovalorizzatore di Modena

    Modena waste-to-energy plant

    Via Cavazza 45, Modena, Italy

    Waste-to-energy plant

    Municipal waste, non-hazardous special waste

    TextSimple in Termovalorizzatore di Modena_ENG

    Overview

    The waste to energy plant is located in Modena in Via Cavazza 45 and is part of a multifunctional hub. The hub also includes a physical/chemical treatment plant for liquid waste managed by Herambiente S.p.A. and of the wastewater treatment plant for the city of Modena managed by Hera S.p.A. The first two lines of the plant, each with a capacity of 140 tons per day, entered into operation in 1980. Subsequently, a third line was built according to the criteria provided for by Presidential Decree 915/82 and with a nominal capacity of 250 tons per day. When the plant came into operation in the early 1990s, the total annual maximum amount of treatable municipal solid waste was 140,000 tonnes per year, while the maximum amount of treatable medical waste did not exceed 5,000 tonnes per year. The lines described above were decommissioned in September 2009 and definitively demolished between May and December 2011 to make way for the new plant. The fourth line was launched in December 2008 for functional testing and in April 2009 for testing with waste. It became fully operational a year later. Page updated on dd/month/yyyy

    ListInfo in Termovalorizzatore di Modena_ENG

    Plant specifications

    Environmental compatibility in compliance with regulations in force (Legislative Decree 152/06)

    • Number of waste to energy lines
      1
    • Total thermal capacity
      about 78 MWt
    • Combustion technology
      water cooled moving grate furnaces
    • Waste disposal capacity
      max 650 t/g with net calorific value (NCV) equal to 10,465 kJ/kg
    • Annual operation
      7,500 hours
    • Nominal electric power
      18.6 MWe
    • Recovery operation
      R1
    • Type of waste accepted
      municipal waste; non hazardous special waste

    BannerImage in Termovalorizzatore di Modena_ENG

    TextPlay in Termovalorizzatore di Modena_ENG

    Technology

    How is the plant built?

    The plant as a whole currently has the following configuration: a waste receiving, storage and feeding section; a combustion line with a mobile grate furnace equipped with a recovery boiler and flue gas cleaning system; and a power generation plant set up for thermal energy recovery.

    Immagine Stone Desktop Termovalorizzatore di Modena
    Cookie disabilitati - contenuto non disponibile

    Title_Term_Modena2 Duplica 1

    Phases of operation

    Accordion_Term_Modena2 Duplica 1

    TextSimple 2 in Termovalorizzatore di Modena - monitoraggio_ENG

    Emissions monitoring

    The plant is equipped with a Continuous Emission Monitoring System (CEMS), which uses automatic analysers operating 24 hours a day to continuously monitor the quality of emissions into the atmosphere.

    HeraTermovalorizzatoriGestoreDati

    The plant is equipped with a Continuous Emissions Monitoring System (CEMS) which has automatic analysers functioning 24 hours per day to continuously monitor the quality of atmospheric emissions. A suitably heated sample probe continuously transports a sample of the gas from the plant´s chimney to the analysis booth where the instrumentation is installed. The sample is put into the Fourier transform infrared spectroscopy (FTIR) analyser, which continuously detects the absorption spectra of the compounds to be measured. A mathematical process is used to compare the spectra with the typical spectra of the substances being investigated. The comparison makes it possible to determine the quantitative values (concentrations) of the elements and compounds analysed. Besides the FTIR system, there are other continuous analysers and meters needed to complete the fume analysis by determining other parameters such as: particles, organic compounds, mercury, oxygen, temperature, flow and pressure. A data acquisition system (SADE) also continuously provides the values obtained by calculating the half-hourly and daily averages of the concentrations measured, which are compared with the maximum admissible limit values set by the Control Bodies. These data are also provided on the group´s website, where they are automatically updated every half hour.

    Emissions report average values of the last half hour

    Type of emission Average values Status
    0,13 40 60 OK
    0 50 200 OK
    50,85 260 400 OK
    0,01 2 4 OK
    0 20 30 OK
    0,71 15 20 OK
    3,7 100 100 OK
    0,36 10 60 OK

    Emissions report average daily values

    10 50 50 200 1 10 10 29,98
    8 50 20 100 1 5 10 5
    03/05/2024 1,63 14,19 0,42 49,25 0,06 0,52 0,94 0,91
    02/05/2024 1,97 11,12 0,45 57,32 0,06 0,5 0,87 0,89
    01/05/2024 1,56 9,2 0,43 66,19 0,06 0,5 1 0,64
    30/04/2024 1,64 11,07 0,43 58,83 0,06 0,5 0,98 0,8
    29/04/2024 1,71 8,78 0,42 50,03 0,06 0,51 0,94 0,9
    28/04/2024 1,84 10,02 0,42 49,25 0,06 0,5 0,86 0,66
    27/04/2024 1,81 13,21 0,42 49,46 0,06 0,5 0,86 0,83
    26/04/2024 1,75 12,34 0,43 50,83 0,06 0,5 0,91 0,76
    25/04/2024 1,91 9,71 0,44 55,67 0,06 0,5 0,85 0,72
    24/04/2024 1,64 8,57 0,43 56,43 0,06 0,5 0,96 0,7

    Select the year

    Type of emission Value
    10 8 1,63
    50 50 14,19
    50 20 0,42
    200 100 49,25
    1 1 0,06
    10 5 0,52
    10 10 0,94
    29,98 5 0,91

    Periodic self-checks for micropollutants - Year 2022

    TIPO EMISSIONE Linea 4 limiti aia Limiti 152/06
    Cd+Tl (mg/Nm3) 0,00051 0,02 0,05
    Hg (mg/Nm3) 0,00119 0,04 0,05
    Metalli (mg/Nm3) 0,0061 0,3 0,5
    Diossine (ng/Nm3) 0,0016 0,05 0,1
    IPA (mg/Nm3) 0,0000022 0,005 0,01
    PCB (ng/Nm3) 0,00074 0,1 0,1

     

     